WATER & PLUMBING

Pipe flow.

Calculate water flow from average velocity and the inside diameter of a full circular pipe. Compare L/s and m³/h without confusing nominal pipe size.

Input guide & diagram
inside daverage velocity

Use clear inside dimensions and average velocity. Nominal DN/NPS is not inside diameter.

Explore unit converters →
PIPE FLOW

Need help? Select ? beside an input.

?

Use average speed across the full pipe or duct, not a peak reading at one point. For duct sizing this is your chosen target speed.

?

Measure the inside diameter. A nominal pipe size such as DN50 is not necessarily a 50 mm inside diameter.

Use a decimal point, for example 12.5.

Volumetric pipe flow
2.94524311274L/s

Cross-sectional area: 0.00196349540849 m²

The pipe is assumed completely full. This is not a calculation for a partly filled drain.

Try an example
Formula and assumptions
Q = v × πd² / 4

Full circular pipe with steady flow and average cross-sectional velocity.

Use inside diameter; nominal DN or NPS is not an inside diameter.

This does not size partially filled gravity drainage, calculate friction loss or assess plumbing code compliance.

Inputs are converted to base units before calculation. Display uses 12 significant digits; accuracy depends on measurements and assumptions. Circular geometry uses an approximate value of π.

Practical guide
TRY THE NUMBERS

Practical examples

Worked example

A full pipe with inside diameter 50 mm and average velocity 1.5 m/s carries approximately 2.945 L/s, or 10.603 m³/h.

READ THE RESULT

How to read the result

  • Flow is volume per time, not water speed or available pressure. Q = average velocity × cross-sectional area.
  • Measure or look up inside diameter for the pipe wall thickness. DN50 does not necessarily mean an inside diameter of 50 mm.
  • This geometry model does not determine friction loss, pump duty or partially filled gravity drainage.

Frequently asked questions

If diameter doubles, does flow double?

At the same average velocity, area and flow increase fourfold because area is proportional to diameter squared.

Does this tell me the flow from water pressure?

No. Pressure, pipe length, fittings and friction need a separate hydraulic model. Enter an independently known average velocity.

UNITNEX

Calculation report

Use your browser's print destination to print or save as PDF.

Install UnitNex

Unit converters and calculators in a dedicated app window.

Choose the install icon in Chrome’s address bar or the install option in its menu. On iPhone or iPad, open UnitNex in Safari and choose Share → Add to Home Screen.

Calculations need an internet connection.