Electrical power.

Calculate active electrical power from voltage and current for DC, single-phase AC or balanced three-phase AC. Distinguish input power from motor output.

Input guide & diagram
V · I · RUse DC or RMS values as specified below

W, VA and var are separate quantities. Use the circuit assumptions below.

Explore unit converters →
ELECTRICAL POWER

Need help? Select ? beside an input.

?

Single-phase AC is common for household appliances; DC is used by batteries. Use three-phase only for a balanced three-phase load.

?

Use the supply voltage from the equipment or circuit. For three-phase calculations enter line-to-line voltage, not phase-to-neutral voltage.

?

Use operating current from the equipment label or a measurement. A is amperes, not power in watts.

?

Power factor is a decimal from greater than 0 up to 1, such as 0.9. Use the equipment value. A simple resistive load is near 1; do not assume the example fits every appliance. DC ignores this value.

Use a decimal point, for example 12.5.

Active electrical power
2.07kW

Active power is the electrical energy use rate, in W or kW. It is different from energy in kWh.

Try an example
Formula and assumptions
DC: P = VI; single-phase: P = VI × PF; three-phase: P = √3 × VLL × IL × PF

AC voltage and current are RMS. For balanced three-phase, enter line-to-line voltage and line current.

Power factor is total active/apparent power ratio. This estimates active input power, not motor shaft output.

Does not select cable, breaker or earthing.

Inputs are converted to base units before calculation. Display uses 12 significant digits; accuracy depends on measurements and assumptions.

Practical guide
TRY THE NUMBERS

Practical examples

Worked example

A single-phase load at 230 V, 10 A and power factor 0.9 uses 230 × 10 × 0.9 = 2.07 kW. At a constant 2.07 kW for 2 hours, energy is 4.14 kWh.

READ THE RESULT

How to read the result

  • kW is active electrical power. kWh is energy over time; use the electricity cost tool to estimate consumption.
  • For AC, enter RMS voltage/current. For balanced three-phase, use line-to-line voltage and line current.
  • Power factor and motor efficiency are different. Motor shaft output also depends on efficiency, which this tool does not apply.

Frequently asked questions

Why is power lower than voltage × current?

For AC, voltage × current gives apparent power in VA for single-phase. Multiplying by total power factor gives active power in W.

May I use a 230 V phase voltage for a 400 V three-phase system?

Select three-phase and enter the actual line-to-line voltage, such as 400 V. Entering 230 V would describe a different voltage basis.